Most multinational Medical Device companies run APAC on a single regulatory playbook: certify the quality system to ISO 13485, manage software under IEC 62304, and treat each country as a registration exercise layered on top. That model holds across much of the region and is the one described in our regional guide to IT for Medical Device companies operating across APAC. It stopped in Japan and South Korea. Both markets re-examine the same ground under their own law, through their own agencies, in their own language, and both attach ongoing data obligations that land directly on the IT estate rather than on the regulatory affairs team alone. This article sets out what changes in each market, what the hospital network requirements mean for connected devices, and how to build the in-country IT layer without duplicating the global stack.
Two Regulators, Two Rulebooks: Where PMDA and MFDS Depart from the Regional Playbook
Japan regulates medical devices under the PMD Act, reviewed by the Pharmaceuticals and Medical Devices Agency (PMDA) with final decisions made by the Ministry of Health, Labor and Welfare. South Korea regulates them under the Medical Device Act and, since January 2025, the Digital Medical Products Act, administered by the Ministry of Food and Drug Safety (MFDS). Neither agency treats a foreign certification as sufficient on its own.
The structural difference from the rest of APAC is that both countries impose a mandatory in-country license holder between the foreign manufacturer and the market. In Japan, a foreign Medical Device company sells through a Marketing Authorization Holder (MAH), or appoints a Designated Marketing Authorization Holder (D-MAH) under the Foreign Special Approval System described by Emergo by UL. In Korea, the equivalent role is the Korea License Holder, which must be a registered Korean business with a full-time quality manager. These are not paperwork formalities. The license holder receives complaints, files adverse event reports, and answers the regulator, which means the systems holding complaint records, distribution data and vigilance workflows must be accessible to a party outside the corporate network, in the local language, on regulatory timelines.
Both regimes also classify devices into four risk classes with different review routes. Japan splits the routes into pre-market notification (Todokede), certification (Ninsho) and approval (Shonin), documented on the PMDA’s English review pages (PMDA, accessed 2026). Korea routes low-risk devices through notification and higher classes through MFDS approval, with KGMP certification as a prerequisite. The practical consequence for IT is the same in both: the regulatory data trail is national, not regional. Our four-market APAC IT compliance reference covers the privacy-law layer; it does not substitute for the device-law layer in these two markets.
Japan: Ordinance 169, the ER/ES Guideline, and Systems the PMDA Can Inspect
Japan’s quality system requirement is MHLW Ministerial Ordinance No. 169, harmonized with ISO 13485:2016 but carrying additional requirements, so an ISO 13485 certificate does not by itself demonstrate compliance, as Emergo by UL’s Ordinance 169 guidance (2024) sets out. Compliance is tested through a QMS conformity investigation by the PMDA or a Registered Certification Body, reaching foreign manufacturing sites and the Japanese license holder together.
For the IT estate, three obligations follow. First, the quality records that the conformity investigation examines, including device master records, complaint files and CAPA workflows, must be producible in Japan, with Japanese-language audit support, on the investigator’s schedule. A validated eQMS hosted in the United States or Europe satisfies this only if access, retention and audit-trail evidence can be demonstrated from the Japanese entity: in practice, an in-country access layer, documented data flows and bilingual system documentation, a real localization cost rather than a translation exercise.
Second, electronic records and signatures used in regulatory submissions fall under the MHLW’s ER/ES Guideline of 2005, Japan’s counterpart to the US 21 CFR Part 11, which defines audit trails, closed and open systems, and the conditions under which electronic signatures are acceptable, summarized in eCompliance’s English rendering of the Japanese ER/ES Guideline. Systems validated against Part 11 usually satisfy the technical controls, but the validation documentation must map to the Japanese guideline explicitly, and the mapping work belongs to whoever runs the system, not the MAH.
Third, Japan’s UDI regime became a legal obligation on 1 December 2022 under the amended PMD Act: barcode labelling in GS1 formats on device packaging, with device data registered into the national database, as reported by Pacific Bridge Medical (2022). That turns labelling from a packaging concern into a master-data pipeline: the systems generating GTINs, lot data and expiry data must feed the Japanese database accurately, and errors surface as compliance findings rather than logistics annoyances. The support model that keeps these systems running inside Japan, vendor and language realities included, is covered in our guide to IT support in Japan for foreign companies.
South Korea: KGMP, the Korea License Holder, and Monthly Data Obligations
Korea’s quality system requirement is KGMP, mandatory for Class II to IV devices and renewed every three years, with the MFDS or its designated bodies auditing both the foreign manufacturing site and the Korea License Holder, as described in ElendiLabs’ Korea registration guide (2025). The three-year renewal cycle is an operational planning fact: each renewal re-opens the audit trail, so systems and records retired or migrated between renewals must remain retrievable: agree the retention architecture before the first migration, not after.
Korea then adds an obligation with no Japanese equivalent in cadence: under the Integrated Medical Device Information System, supply information, meaning who received the devices and in what quantity, must be reported monthly through the Korea License Holder, alongside UDI registration, per Pacific Bridge Medical’s 2025 Korea regulatory update. A monthly, per-transaction reporting duty makes the ERP-to-regulator data flow a production system. If distribution data lives in a regional ERP instance and the Korea License Holder works from spreadsheets, the reconciliation burden lands on people, and a missed month is a regulatory event.
The newest layer is the Digital Medical Products Act, in force since 24 January 2025, which regulates digital medical devices and software as their own category, with manufacturing and quality standards for digital medical device software issued in April 2025 and further provisions, including software labelling, taking effect from 24 January 2026, per Emergo by UL (2025). For software-driven devices the useful feature is the pre-approved change management plan, which allows algorithm updates within approved parameters without full re-approval. The trade-off: the change-control discipline it presumes, versioned builds, documented update channels, evidence of what shipped where, must exist in the toolchain before the plan is filed. How to stand up and run the infrastructure underneath this in Korea is covered in our guide to IT infrastructure management for foreign companies operating in Korea.
Connected Devices on Hospital Networks in Tokyo and Seoul
A connected device does not only face the device regulator. It sits on a hospital network, and both countries have tightened what those networks must enforce, changing what a Medical Device company must demonstrate before a hospital IT department will connect its product.
In Japan, the MHLW’s Guidelines for the Safety Management of Medical Information Systems were revised to Version 6.0 in May 2023, restructured into governance, management and control volumes after ransomware incidents at Japanese hospitals and the mandatory move to online insurance verification, as tracked by Digital Policy Alert (2023). Hospitals subject to these guidelines push the requirements down to vendors: network segmentation for device traffic, documented remote-maintenance channels rather than ad hoc remote access, and security documentation a hospital committee can review in Japanese. In Korea, the MFDS has published cybersecurity review guidance for connected devices and, under the Digital Medical Products Act framework, security requirements covering encryption, access control and vulnerability monitoring across the product lifecycle, per Pacific Bridge Medical (2025).
Patient and complaint data flowing off these devices adds the privacy layer. Japan’s APPI, supervised by the Personal Information Protection Commission, and Korea’s PIPA both condition cross-border transfers, with PIPA requiring disclosure and consent or another lawful route for sending personal data abroad, as summarized by Securiti’s PIPA overview. The engineering consequence: telemetry and complaint-handling pipelines that copy identifiable Japanese or Korean patient data into a global data lake by default need a lawful-transfer design, or a redesign that de-identifies at the edge. De-identification at the edge costs analytics fidelity; lawful-transfer mechanisms cost legal and administrative overhead per data flow. One of the two costs must be chosen deliberately.
Building the In-Country Layer Without Duplicating the Global Stack
The wrong response is to clone the global IT estate into Tokyo and Seoul. Full duplication doubles licensing, validation and support cost, and creates two more validated environments to keep in sync with every global change. The workable pattern is a thin, defensible in-country layer over a global core, drawn along the lines the regulators actually test.
The comparison below shows where the two markets impose the same kind of obligation and where they diverge, which determines what can be shared and what cannot.
| Obligation | Japan | South Korea |
|---|---|---|
| Device law and regulator | PMD Act; PMDA reviews, MHLW decides | Medical Device Act + Digital Medical Products Act; MFDS |
| Quality system standard | MHLW Ordinance No. 169 (ISO 13485-based, with additions) | KGMP, renewed every three years |
| Mandatory local role | MAH or D-MAH | Korea License Holder with full-time quality manager |
| Electronic records rule | ER/ES Guideline (2005) | DMPA software quality standards (2025) |
| Recurring data duty | UDI registration in the national database | UDI plus monthly supply-information reporting |
| Hospital network frame | MHLW Safety Management Guidelines v6.0 (2023) | MFDS cybersecurity review guidance; DMPA security provisions |
Reading the table operationally: the quality system core, the eQMS, document management and CAPA platform, can stay global, provided each market gets a documented access layer, market-specific validation mapping (Ordinance 169 and ER/ES for Japan, KGMP and DMPA standards for Korea) and bilingual audit artifacts. The data pipelines cannot stay purely global: Japan’s UDI feed and Korea’s monthly supply reporting are national interfaces that need owned, monitored integrations. Support and audit response must be local in language and time zone, because a QMS conformity investigation in Osaka and a KGMP renewal audit in Seoul both run in the local language on local schedules.
The honest trade-off of the thin-layer model is coordination overhead. Every global platform change carries two market-mapping reviews, and the in-country access layers need real ownership rather than a nominal contact. Companies that skip the ownership question end up rebuilding the layer under audit pressure, which is the most expensive possible schedule. For most foreign Medical Device companies the sequencing that works is to build the Japan layer first where revenue weight justifies it, reuse the architecture patterns for Korea, and resist per-country tool purchases unless a national interface forces one.
Frequently Asked Questions
Does Japan have an FDA equivalent?
Yes, functionally. The Pharmaceuticals and Medical Devices Agency (PMDA) conducts scientific review of medical devices, and the Ministry of Health, Labor and Welfare issues final approvals under the PMD Act. Unlike the FDA, market access also requires an in-country Marketing Authorization Holder to hold the license and face the regulator.
What are the regulatory requirements for medical devices in Japan?
Classification into one of four risk classes, then notification, certification or PMDA approval depending on class; compliance with the quality system requirements of MHLW Ordinance No. 169; an in-country MAH or D-MAH; UDI barcode labelling with registration in the national database; and post-market vigilance run through the Japanese license holder.
Is ISO 13485 certification enough for Japan and South Korea?
No. Japan’s Ordinance 169 is harmonized with ISO 13485:2016 but adds requirements, and compliance is verified through a Japanese QMS conformity investigation. Korea requires KGMP certification, audited separately and renewed every three years. ISO 13485 shortens the distance in both markets but substitutes for neither national requirement.
Who holds a medical device license in South Korea for a foreign manufacturer?
A Korea License Holder: a registered Korean business with a full-time quality manager that holds the product licenses, files adverse event and monthly supply reports through the Integrated Medical Device Information System, and represents the manufacturer to the MFDS. Its effectiveness depends on the data access the manufacturer’s systems give it.
Can device and patient data from Japan or South Korea be processed at regional headquarters?
Only with a deliberate transfer design. Japan’s APPI and Korea’s PIPA both condition cross-border transfers of personal data, with PIPA requiring disclosure and consent or another lawful route. Telemetry and complaint pipelines should either de-identify data before it leaves the country or run on a documented lawful-transfer mechanism.
Does systemsGo support Medical Device companies operating in Japan and South Korea?
Yes. systemsGo runs IT operations for foreign multinationals in both markets, with offices and engineers in Japan and Korea, and supports regulated environments with bilingual audit-ready documentation, in-country infrastructure and support, and the network segmentation and remote-maintenance arrangements hospital deployments require.
If Japan and South Korea are next on your device program’s map, the IT layer decides how smoothly the regulatory layer runs. systemsGo designs and operates that in-country layer, from validated system access to hospital network requirements, across both markets.